Building Glass Special Optical Transmittance Detector
Building Glass Special Optical Transmittance Detector
next
prev
Video
1/2

Building Glass Special Optical Transmittance Detector

Price
MOQ
$1799
10 Pieces
Product Details
Detection Wavelength Range:
380-780nm
Transmittance Detection Accuracy:
±0.2%
Compatible Sample Size:
Max 1.5m x 2m
Shipping & Policy
Shipping & Delivery Info:
Contact the supplier for details on freight charges and estimated delivery time—tailored to your order and shipping requirements.
Payment Methods:
T/T PayPal
Support payments in USD
Transaction Security Guarantee:
Our platform strictly verifies suppliers’ and buyers’ qualifications to ensure authenticity & legitimacy, creating a reliable trade environment and reducing risks.
After-Sales Support:
For issues like mismatched product quality or delivery delays, we offer assistance—intervening to coordinate and resolve problems per contracts/rules, safeguarding your rights.
Our Store's Similar Products
Product Description
Company Info

Basic Info

This special optical transmittance detector for building glass is designed for building glass production, curtain wall construction and door and window quality inspection scenarios. It features accurate detection in the visible light band, and can quickly detect the transmittance of various building glasses, helping building material enterprises control product quality. It solves the pain points of traditional detection methods with complicated operations and low efficiency, and adapts to on-site detection needs in the construction industry.

Key attributes

Detection Wavelength Range
380-780nm
Transmittance Detection Accuracy
±0.2%
Compatible Sample Size
Max 1.5m x 2m
Detection Modes
Single-point scanning + regional detection
Battery Life
6 hours per charge
Net Weight
5.5kg
Interface Types
USB-C, Bluetooth 5.0
Certifications
CE, RoHS
Protection Level
IP53
Calibration Method
Automatic calibration + glass standard sheet
Data Synchronization
Mobile APP synchronization
Detection Wavelength Range
380-780nm
Transmittance Detection Accuracy
±0.2%
Compatible Sample Size
Max 1.5m x 2m
Detection Modes
Single-point scanning + regional detection
Battery Life
6 hours per charge
Net Weight
5.5kg
Interface Types
USB-C, Bluetooth 5.0
Certifications
CE, RoHS
Protection Level
IP53
Calibration Method
Automatic calibration + glass standard sheet
Data Synchronization
Mobile APP synchronization

Customer reviews

Michael · Architectural Engineer
The dedicated optical transmittance detector for architectural glass has been a game-changer for our quality control process. Its high-precision measurements allow us to verify glass specifications with 0.1% accuracy, which is crucial for meeting LEED certification requirements. We particularly appreciate the automatic temperature compensation feature that ensures consistent readings in our variable climate conditions.

Product Description

Product features:

It adopts a high-sensitivity detector dedicated to the visible light band, with a detection accuracy of ±0.2%, fully meeting the transmittance detection standards for building glass. It supports two modes: single-point scanning and regional detection, which can accurately detect local defects of glass. The whole machine weighs only 5.5kg, and is equipped with a retractable detection bracket to adapt to glass curtain wall detection of different heights. It is equipped with Bluetooth 5.0 and USB-C interfaces, which can synchronize detection data to the supporting mobile APP in real time and generate intuitive transmittance test reports. It has an IP53 protection level, which can cope with dust and slight splashing at construction sites. It is equipped with one-click automatic calibration function, which does not require professional personnel to complete the calibration operation, simplifying the detection process. The lightweight aluminum alloy body is paired with anti-slip rollers, making it easy to move and use on construction sites.

https://globalsyt.oss-accelerate.aliyuncs.com/materials/185/0/20260306135933_69aa6d45c9a51.webp

Product specifications:

The detection wavelength range is 380nm to 780nm visible light band, fully covering the common detection spectrum of building glass. The transmittance detection accuracy is ±0.2%, and the single detection time is ≤2 seconds. It is compatible with building glass samples with a maximum size of 1.5m (width) × 2m (length), and supports customized large-scale glass detection fixtures. The overall dimensions are 500mm (length) × 400mm (width) × 200mm (height), with a net weight of 5.5kg. It has a built-in 8000mAh rechargeable lithium battery, supporting 6 hours of continuous detection, and supports USB-C fast charging. It has obtained CE and RoHS certifications, meeting EU building material detection standards. The data storage capacity reaches 3000 sets of test results, supporting export to computers via USB-C interface or synchronization to the supporting mobile APP via Bluetooth 5.0. It has an IP53 protection level, which can cope with the harsh environment of construction sites.

https://globalsyt.oss-accelerate.aliyuncs.com/materials/185/0/20260306135934_69aa6d464f871.jpg

Product application:

It is suitable for on-line quality inspection of building glass manufacturers, on-site detection at building curtain wall construction sites, finished product quality inspection of door and window enterprises, and glass performance detection of third-party building material testing institutions. It can quickly detect the transmittance parameters of various building glasses such as tempered glass, hollow glass, laminated glass and coated glass, helping enterprises timely detect unqualified products and ensure that the lighting performance of building curtain walls and doors and windows meets the design standards. Typical application scenarios include finished product spot check in glass production workshops, lighting performance acceptance after building curtain wall installation, and product display detection in door and window stores.

Frequently Asked Questions (FAQ)

Q:What are the key features of architectural glass optical transmittance testers?
A:Architectural glass optical transmittance testers measure light transmission (typically 80-90% for clear glass) with ±0.5% accuracy. They feature large sample holders (up to 300x300mm) and comply with ISO 9050/EN 410 standards for building materials testing.

Company Profile

Business Type:
Manufacturer
Main Products:
Optical transmittance detector,intelligent robot,Industrial automation system,Machinery and equipment
Year of Establishment:
2015
Number of Employees:
5-10 People
Address:
No. G3004, 3rd Floor, Building B, Qinhan Innovation Center, Yaodian Street Office, Qinhan New City, Xixian New Area, Shaanxi Province, Xianyang, Shaanxi, China
Average Response Time:
14 Days

General Information

Business Type:
Manufacturer
Main Products:
Optical transmittance detector,intelligent robot,Industrial automation system,Machinery and equipment
Year of Establishment:
2015
Number of Employees:
5-10 People
Management System Certification:
HACCP,TL900,QS9000,SA8000,ISO9001,ISO9004,ISO17799,ISO9000,ISO14000,ISO10441,ISO16949,TS16969,ISO19011:2000,OHSAS18001,Others
Address:
No. G3004, 3rd Floor, Building B, Qinhan Innovation Center, Yaodian Street Office, Qinhan New City, Xixian New Area, Shaanxi Province, Xianyang, Shaanxi, China

Trade Capability

Main Markets:
北美,南美洲,东欧,东南亚,非洲,大洋洲,中东,东亚,西欧,中美洲,北欧,南欧,南亚,国内市场
Shipping Ports:
Export Volume:
US$1.5 Million-US$2.5 Million
Average Lead Time:
14 Days
Payment Terms:
T/T L/C MoneyGram PayPal D/P Western Union Others
Cooperation Mode:
OEM ODM
Customization Supported:
No
Number of Foreign Trade Sales Staff:
5-10 People
Overseas Agent / Overseas Branch:
No

Company Show

Qualification Certificate
>
<
Cases
>
<
Contact this supplier now
*From:
*To:
Mr. Zhai Ziyi
General Manager / board of directors
*Message:
Send
Start Order Request Contact Supplier
Chat
New Products
Product Groups
Find Similar Products By Category
scroll_to_top